Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kidney Blood Press Res ; 48(1): 231-240, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36882038

RESUMO

INTRODUCTION: Chronic kidney disease-mineral and bone disorder (CKD-MBD) is frequently observed in maintenance hemodialysis (MHD) patients and is associated with fracture, muscle weakness, malnutrition, etc.; however, relationships of CKD-MBD markers and fatigue are not well established. METHODS: This was a cross-sectional study including 244 MHD patients (89 elders) from July to September 2021 in the First Affiliated Hospital of Shandong First Medical University. CKD-MBD markers and other clinical data were collected from medical records. Fatigue in the past week was measured by Standardized Outcomes in Nephrology-Hemodialysis (SONG-HD) fatigue measure; fatigue at the end of hemodialysis was measured by numeric rating scale (NRS). Spearman correlation, linear regression, and robust linear regression were. RESULTS: In all MHD patients, lg[25(OH)D] (nmol/L) was negatively correlated with SONG-HD score (ß = -1.503, 95% CI: -2.826 to 0.18, p = 0.026) and NRS score (ß = -1.532, p = 0.04) in multiple regression models adjusting for sex, age, and all CKD-MBD characters; but no correlations were found on univariate regression or in other multiple regression models. Interaction effects between age ≥65 years and lg(25[OH]D [nmol/L]) in terms of fatigue scores were significant based on multiple linear regressions (SONG-HD score ß = -3.613, p for interaction = 0.006; NRS score ß = -3.943, p for interaction = 0.008). Compared with non-elderly patients, elderly patients were with higher ACCI scores (7 [6, 8] vs. 4 [3, 5], p < 0.001), higher SONG-HD scores (3 [2, 6] vs. 2 [1, 3], p < 0.001), higher NRS score (4 [2, 7] vs. 3 [1, 5], p < 0.001), lower serum phosphate levels (1.65 [1.29, 2.10] vs. 1.87 [1.55, 2.26] mmol/L, p = 0.002), and lower serum iPTH levels (160.6 [90.46, 306.45] vs. 282.2 [139, 445.7] pg/mL, p < 0.001). There were no differences in serum calcium, alkaline serum, or 25(OH)D levels between the two groups. In elderly patients, lg[25(OH)D] was negatively correlated with SONG-HD score (ß = -3.323, p = 0.010) and NRS score (ß = -3.521, p = 0.006) on univariate linear regressions. Following adjustment for sex, age, and all CKD-MBD characters, lg[25(OH)D] was negatively correlated with SONG-HD scores (multiple linear regression ß = -4.012, p = 0.004; multiple robust regression ß = -4.012, p = 0.003) or NRS scores (multiple linear regression ß = -4.104, p = 0.002; multiple robust regression ß = -4.104, p = 0.001). There were no significant correlations between fatigue scores and other CKD-MBD markers (calcium, phosphate, lgiPTH, alkaline phosphatase) in elderly MHD patients, on either univariate linear regressions or multiple regressions. CONCLUSION: Serum 25(OH)D level is negatively associated with fatigue in elderly MHD patients.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Humanos , Idoso , Pessoa de Meia-Idade , Cálcio , Estudos Transversais , Diálise Renal , Fadiga/etiologia , Fosfatos , Hormônio Paratireóideo
2.
Sensors (Basel) ; 20(5)2020 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-32164374

RESUMO

This paper presents an approach to analyse the quality, in terms of precision and reliability, of a system which integrates-at the observation-level-landmark positions and GNSS measurements, obtained with a single camera and a digital map, and a single frequency GNSS receiver respectively. We illustrate the analysis by means of design computations, and we present the actual performance by means of a small experiment in practice. It is shown that the integration model is able to produce a position solution even when both sensors individually fail to do so. With realistic assumptions on measurement noise, the proposed integrated, low-cost system can deliver a horizontal position with a precision of better than half a meter. The external reliability of the integrated system is at the few decimetre-level, showing that the impact of undetected faults in the measurements, for instance incorrectly identified landmarks in the image, on the horizontal position is limited and acceptable, thereby confirming the fault-robustness of the system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...